ConceptWall 86 Functional
Technical informationPerformance
Comfort
- Air tightness
- AE 900 (900Pa)
- Water tightness
- Class E900 (900Pa)
- Wind load resistance
- Class A5 (2000Pa)
Safety
- Burglar resistance
- RC2
- Impact resistance
- I5 - E5
Properties
Max. dimensions & weight
- Min. height of vent
- 23 5/8 inch
- Max. height of vent
- 78 3/4 inch
- Min. width of vent
- 17 11/16 inch
- Max. width of vent
- 59 1/16 inch
- Max. weight of vent
- 330 lbs
- Min. intertia mullion - Ix
- 114.8 cm4
- Max. intertia transom - Ix
- 435.83 cm4
- Min. intertia transom - Iy (glass load)
- 51.6 cm4
- Max. intertia transom - Iy (glass load)
- 153.38 cm4
Sightlines
- Min. width T-profile
- 3 3/8 inch
- Min. visible width (interior view)
- 3 3/8 inch
- Min. visible width (exterior view)
- 2 11/16 inch
- Min. depth mullion
- 7 11/16 inch
- Min. depth transom
- 7 11/16 inch
Glazing
- Rebate height
- 1 inch
- Glazing method
- Dry glazing - Siliconized glazing - External glazing - Glazing bead
- Min. glass thickness - frame/element
- 3/16 inch
- Max. glass thickness - frame/element
- 1 1/2 inch