Skip to main content

ConceptSystem 77 Hidden Vent

Technical information

Performance

Energy

Thermal insulation - Uw Double
0.24 Btu/hr.ft².°F
Thermal insulation - Uw Triple
0.18 Btu/hr.ft².°F
Uw Dependencies
Frame-vent: Ug 1.0W/m²K, warm edge spacer,@1.23x1.48m (78mm sight line), 36mm glass

Comfort

Air tightness
0.04 cfm/ft³
Water tightness
12 psf
Air tightness
Class 4 (600Pa)
Water tightness
Class E750 (750Pa)
Wind load resistance
Class C4 (1600Pa)
AMAA rating
Class AW
PG rating
120
Acoustics STC
43 dB
Acoustics OITC
34 dB
Opening & closing resistance
Class 3

Safety

Burglar resistance
RC2
Operating Forces Class
Class 1
* Note: Performances and properties may be different depending on the profile combinations

Properties

Max. dimensions & weight

Min. height of vent
21 5/8 inch
Max. height of vent
94 1/2 inch
Min. width of vent
21 5/8 inch
Max. width of vent
55 1/8 inch
Max. weight of vent
264 lbs

Sightlines

Min. frame width (inward opening)
3 inch
Min. vent width (inward opening)
inch
Min. frame-vent width (inward opening)
3 inch
Min. vent-vent width (inward opening)
4 5/8 inch
Min. width T-profile
4 inch
Depth frame
2 11/16 inch
Depth Vent
2 7/8 inch
Depth frame-vent
3 1/16 inch

Glazing

Rebate height
3/4 inch
Glazing method
Dry glazing - Siliconized glazing - Internal glazing - External glazing - Glazing bead
Min. glass thickness - frame/element
3/16 inch
Max. glass thickness - frame/element
1 7/8 inch
Min. glass thickness - vent
13/16 inch
Max. glass thickness - vent
1 7/8 inch